

"Very simple and elegant product to locate tight contact areas. Not messyy like sprays and more accurate than using floss."
Microcopy
P.O. Box 2017
Kennesaw, Ga 30156-9017
P: 800.235.1863
F: 770.423.4996
011M (Ball) 25 Pack
QTY: 2
X
$97.00
011M (Ball) 25 Pack
QTY: 2
X
$97.00
Microcopy respects the privacy of our customers and pledges to not sell or give out your email address or login information to any 3rd party. You will receive occasional emails from Microcopy alerting you to new products, or related company information.
You can elect to not receive these messages at any time by clicking the Unsubscribe link within the email. Be sure to use a valid email address when you register/sign in so that you can reset your password or, if need be, cancel your account, at any time.
STANDARD TERMS AND CONDITIONS OF SALE
SPECIAL EXPORT TERMS AND CONDITIONS OF SALE
RETURNS POLICY
Microcopy will accept returns from US and Canada direct customers once an approved Return Authorization number has been recorded. All returns older than 1 year will require a 15% restocking charge. No returns will be accepted after 3 years from original ship date. All shipment of goods outside of the continental US is final.
REMOVE
0110M (1)
Medium Grit
25/PK
$48.50
Reference F/G | 801-018 |
Head Diameter | 1.8 mm |
Head Length | 1.6 mm |
Overall Length | 19.2 mm |
Reference F/G
801-018
Head Diameter
1.8 mm
Head Length
1.6 mm
Overall Length
19.2 mm
No other grits offered for this shape
REMOVE
0112M (2)
Medium Grit
25/PK
$48.50
Reference F/G | 801-018 |
Head Diameter | 1.8 mm |
Head Length | 1.6 mm |
Overall Length | 19.2 mm |
Reference F/G
801-018
Head Diameter
1.8 mm
Head Length
1.6 mm
Overall Length
19.2 mm
No other grits offered for this shape
REMOVE
0116C (4)
Coarse Grit
25/PK
$48.50
Reference F/G | 801-018 |
Head Diameter | 1.8 mm |
Head Length | 1.6 mm |
Overall Length | 19.2 mm |
Reference F/G
801-018
Head Diameter
1.8 mm
Head Length
1.6 mm
Overall Length
19.2 mm
Medium (0116M)
Bridge/Operative
Ball
Beveled Cylinder
Dbl Inverted Cone
Egg
End Cutter
Flame
Flat End Cylinder
Flat End Taper
Mod. Flat End Cylinder
Interproximal
Football
Gross Reduction
Inverted Cone
Mod. Bevedled Cylinder
Mod. Flat End Taper
Occlusal Reduction
Pear
Occlusal Reduction
Depth Cutter
Endo
End Cutting
Finishing
Guide-Pin
NeoSpiral
0110M (1)
Medium Grit
25/pk
$48.50
3120 Moon Station Rd, NW | Kennesaw, GA 30144 | 800.235.1863
Dear Customer,
Sometimes the smallest gesture can have the biggest impact. Let me explain. Given the current weariness of everyone during this unprecedented time, it’s more important than ever for us as dental professionals to help the community feel safe and comfortable about coming back to dental offices. We know everyone is anxious and we should be doing anything and everything we can to remove that anxiety. The thing at the forefront of everyone’s mind is infection control and cleanliness. As the market leader of SPU (single-patient-use) burs, we firmly believe that one way you can reduce your patients’ fears about cleanliness is by using a fresh bur for every procedure. It’s been proven time and time again that multi-use burs cannot be sterilized 100% of the time. Ease your patients’ minds by showing them the sterile packet and opening the bur in front of them. This shows that you’re using sterile products, but more importantly it shows them that you care—it shows your dedication to them and their health, and that you are doing your part in easing their minds during this time. It’s a small gesture, but it will make a big impact. We have started a new campaign titled SPU4U. Educating the patient that you and your practice are single-patient-use for THEM.
You got this.
Paul Tucker
CEO | Microcopy
CAUTION:
Rx Only. These instructions, in whole or in part, are not a substitute for formal training in diamond dental burs. Appropriate professional education is STRONGLY RECOMMENDED prior to using this device clinically.
DESCRIPTION:
Microcopy NeoDiamond burs are manufactured from a single piece of high-quality stainless steel plated at the operational end with a natural diamond grit. The diamond burs are further plated with a unique protective coating formula. The range includes patterns designed to meet the needs of all surgery and laboratory applications. The burs are packed in a plastic pouch in a dedicated cleanroom facility and terminally sterilized using Gamma Irradiation. These burs are identified as sterile single-use devices and NOT be re-processed and/or re-used.
INDICATIONS
Microcopy NeoDiamond diamond burs can be used to cut a wide variety of materials encountered in dentistry. These include tooth material such as enamel, dentin and bone, dental materials such as amalgam, composite, glass-ionomer cements, polymer and ceramics and precious and non-precious alloys.
CONTRAINDICATIONS TO USE
Use of Microcopy NeoDiamond is contraindicated on any patient who is allergic to any of the components of the product. Do not reuse. Microcopy NeoDiamond are single-use. Attempts to reuse these products will adversely affect their performance.
CLINICAL PRECAUTIONS AND WARNINGS:
Instrument head diameter 01/10 (mm) - ISO |
Maximum permissible speed (RPM) |
Recommended operational speed (RPM) |
007 - 010 | 450,000 | 100,000 - 220,000 |
011 - 014 | 450,000 | 70,000 - 220,000 |
015 - 018 | 450,000 | 55,000 - 160,000 |
019 - 023 | 300,000 | 40,000 - 120,000 |
024 - 027 | 160,000 | 35,000 - 110,000 |
028 - 031 | 140,000 | 30,000 - 95,000 |
032 - 040 | 95,000 | 25,000 - 75,000 |
041 - 054 | 95,000 | 15,000 - 60,000 |
055 - 070 | 60,000 | 12,000 - 40,000 |
080 - 100 | 45,000 | 10,000 - 20,000 |
CLINICAL USE:
Microcopy NeoDiamond burs can be used to cut a wide variety of materials encountered in dentistry. These include tooth material such as enamel and dentin, dental materials such as composite, glass-ionomer cements, polymer and ceramic and precious and non-precious alloys. Our range of diamond burs provide maximum cutting efficiency and effortless access through tough diamond for both endodontic treatment and crown removal.
Holding the bur in the pouch by the operative end, push the stem end through the plastic far enough to insert into the handpiece collet. Immediately insert the stem into the handpiece collet and tighten before releasing the grip on the operative end and discarding the empty pouch.
STORAGE (PRE-USE):
Store in a dry and clean environment at ambient temperature.
Protect instruments in general against chemicals, acids, heat and extreme temperature variations.
STERILE PRODUCT SHELF LIFE:
TRACEABILITY:
Each package includes Lot number on its label.
This number must be quoted in any correspondence regarding the product.
APPLICABLE SYMBOLS:
![]() |
Manufacturer | Indicates the medical device manufacturer. |
![]() |
Do not reuse | Indicates a medical device that is intended for one use, or for use on a single patient during a single procedure. |
![]() |
Do not resterilize | Indicates a medical device that is not to be re-sterilized. |
![]() |
Sterilized using irradiation | Indicates a medical device that has been sterilized using irradiation. |
![]() |
Batch Code | Indicates the manufacturer's batch code so that the batch or lot can be identified. |
![]() |
Consult instructions for use | Indicates the need for the user to consult the instructions for use. |
![]() |
Use by date | Indicates the date after which the medical device is not to be used. |
![]() |
Do not use if package is damaged | Indicates a medical device that should not be used if the package has been damaged or opened. |
![]() |
CE marking | Indicates European Conformity Mark. |
![]() |
Authorized European representative | Indicates the Authorized representative in the European Community. |
![]() |
Keep Dry | Indicates a medical device that needs to be protected from moisture. |
![]() |
DEVICE for professional use only |
(ref US FDA CDRH) Indicates device shall only be used by a trained professional. |
![]() |
Medical Device | Indicates device is designed and intended for medical use. |
![]() |
Catalog Number | Indicates the manufacturer's catalog number so that the medical device can be identified. |
![]() |
Single Patient – Multiple Use | Indicates a medical device that may be used multiple times in a single operation. |
![]() |
Max speed | Indicates Max speed |
![]() |
Wear eye protection | Indicates that eye protection must be used. |
![]() |
Wear a mask | Indicates that a face mask must be worn. |
CONTACT INFORMATION:
![]() |
Microcopy Dental |
![]() |
Obelis S.A |
![]() |
0483 |
This section is deivided into 2 sections to allow a quick and practical access to the Instructions For Use (IFU) of Microcopy products. Upon request you can contact Microcopy to order a free of charge copy of any IFU. More details below.
1. Current Valid IFU
NEODIAMOND
IFU for NeoDiamond
Upon request, you can contact Microcopy to order a free of charge copy of any IFU. Timetable of receiving the IFU: by Email - 2 working days, by mail - 7 working days.
If you would like to conact our webmaster for any comments or suggestions, please feel free to do so at This email address is being protected from spambots. You need JavaScript enabled to view it..
CAUTION:
Rx Only. These instructions, in whole or in part, are not a substitute for formal training in carbide dental burs. Appropriate professional education is STRONGLY RECOMMENDED prior to using this device clinically.
DESCRIPTION:
Microcopy NeoBurr tungsten carbide burs are manufactured from either a single piece tungsten carbide or, from a tungsten carbide tip, brazed to a surgical grade stainless steel stem. The range includes patterns designed to meet the needs of all surgery and laboratory applications. The burs are packed in a plastic pouch in a dedicated cleanroom facility and terminally sterilized using Gamma Irradiation by a contract sterilizer. These burs are identified as single-use devices and should NOT be re-processed and/or re-used.
INDICATIONS:
Microcopy NeoBurr tungsten carbide burs can be used to cut or finish a wide variety of materials encountered in dentistry. These include tooth material such as enamel, dentin and bone, dental materials such as amalgam, composite, glass-ionomer cements, polymer and ceramic and precious and non-precious alloys.
CONTRAINDICATIONS TO USE:
Use of Microcopy NeoBurr is contraindicated on any patient who is allergic to any of the components of the product.
Do not reuse. Microcopy NeoBurr are single-use. Attempts to reuse these products will adversely affect their performance.
CLINICAL PRECAUTIONS AND WARNINGS:
Instrument head diameter |
Maximum permissible speed |
Recommended operational speed (RPM) |
007 - 010 | 450,000 | 100,000 - 220,000 |
011 - 014 | 450,000 | 70,000 - 220,000 |
015 - 018 | 450,000 | 55,000 - 160,000 |
019 - 023 | 300,000 | 40,000 - 120,000 |
024 - 027 | 160,000 | 35,000 - 110,000 |
028 - 031 | 140,000 | 30,000 - 95,000 |
032 - 040 | 120,000 | 25,000 - 75,000 |
041 - 054 |
95,000 | 15,000 - 60,000 |
055 - 070 | 60,000 | 12,000 - 40,000 |
041 - 054 | 45,000 | 10,000 - 20,000 |
CLINICAL USE:
Microcopy’s tungsten carbide burs can be used to cut or finish a wide variety of materials encountered in dentistry. These include tooth material such as enamel, dentin and bone, dental materials such as amalgam, composite, glass-ionomer cements, polymer and ceramic veneers and precious and non-precious alloys. The bur pattern will be selected to cut a specific material in a specific application.
Holding the bur in the pouch by the operative end, push the stem end through the plastic far enough to insert into the hand piece collet. Immediately insert the stem into the handpiece collet and tighten before releasing the grip on the operative end and discarding the empty pouch.
STORAGE:
In dry conditions and protected against contaminants. Protect instruments, in general, against chemicals, acids, heat and extreme temperature variations.
STERILE PRODUCT SHELF LIFE:
TRACEABILITY:
Each package includes Lot number on its label.
This number must be quoted in any correspondence regarding the product.
APPLICABLE SYMBOLS:
![]() |
Manufacturer | Indicates the medical device manufacturer. |
![]() |
Do not reuse | Indicates a medical device that is intended for one use, or for use on a single patient during a single procedure. |
![]() |
Do not resterilize | Indicates a medical device that is not to be re-sterilized. |
![]() |
Sterilized using irradiation | Indicates a medical device that has been sterilized using irradiation. |
![]() |
Lot Code | Indicates the manufacturer's batch code so that the batch or lot can be identified. |
![]() |
Consult instructions for use | Indicates the need for the user to consult the instructions for use. |
![]() |
Use By | Indicates the date after which the medical device is not to be used. |
![]() |
Do not use if package is open or damaged | Indicates a medical device that should not be used if the package has been damaged or opened. |
![]() |
CE marking | Signifies European technical conformity. |
![]() |
Authorized European representative | Indicates the Authorized representative in the European Community. |
CONTACT INFORMATION:
![]() |
Microcopy Dental |
![]() |
DENTEQ Medical Technologies |
![]() |
0483 |
This section is deivided into 2 sections to allow a quick and practical access to the Instructions For Use (IFU) of Microcopy products. Upon request you can contact Microcopy to order a free of charge copy of any IFU. More details below.
1. Current Valid IFU - section for current valid documents.
NEOBURR
IFU for NeoBurr
2. Archived (previous) IFU's - obsolete versions of the documents.
NEOBURR
IFU for NeoBurr
Upon request, you can contact Microcopy to order a free of charge copy of any IFU. Timetable of receiving the IFU: by Email - 2 working days, by mail - 7 working days.
If you would like to conact our webmaster for any comments or suggestions, please feel free to do so at This email address is being protected from spambots. You need JavaScript enabled to view it..